CMD (craniomandibular dysfunction) is a collective term for different types of disorders of the normal function of the masticatory organ (also called "masticatory apparatus", comprising teeth, jaws, tongue, temporomandibular joints, masticatory musculature, neural circuits involved and adjacent anatomical structures) with multiple symptoms. Alternative terms are craniovertebral dysfunction (CVD), myoarthropathy, stomatognathic dysfunction, temporomandibular dysfunction (TMD) etc.
The symptoms of CMD can be roughly divided into the areas of joint problems (arthropathy), displacement of the disc (discopathy), myofacial pain (myopathy) and other physical and psychological symptoms. In particular in the temporomandibular joint it can lead to pain, cracking or rubbing noises, restriction of the mouth opening or even to lockjaw. There may be lateral deflection, deviation from the straight, vertical mouth opening. Increased mobility of the mandible is also possible; the mandible can also dislocate (lockjaw, luxation), e.g. with a wide yawn. Frequently tension and pain may occur in the regions of the masticatory musculature, head, face and neck. In rare cases earache, ringing in the ears (tinnitus), dry mouth or taste disorders can also occur.
In addition to a general dental examination and diagnosis, first an orientating test (rapid test) is required in cases with indications for CMD followed by comprehensive diagnosis of the masticatory system (functional analysis, functional diagnostics) for detection and more precise determination of CMD. This includes manual examination of temporomandibular joints and musculature (manual functional analysis), with special measuring devices (instrumental functional analysis) and often also special X-rays (temporomandibular joint X-ray) as well as standardised questionnaires for collecting specific patient case histories. Findings are recorded and evaluated in a standardised form (functional status).
Apart from general illnesses (rheumatics, arthritis, muscle and nerve diseases), possible causes of CMD are congenital and acquired tooth malalignment (tipping, rotation, extension), intercuspation and occlusal relationship disorders ("occlusopathy", cross-bite, edge-to-edge bite, deep overbite, open bite), diastemas, incorrect vertical relationship of dentures, bridges, crowns or fillings, misalignment of the locomotor system, accidents, overloading and overstretching (power sports, intensive chewing of gum, long-term tooth treatments, operations under general anaesthetic, parafunctions (habits) such as biting nails/pencils and bruxism (clenching, grinding) and also stress and mental/psychological strains and disorders (psychosis, depression, anxiety disorders). There is seldom only one single cause; mainly several factors are collectively involved in the development of CMD (multifactorial aetiology).
Many dysfunctions are low grade and harmless. Serious dysfunctions can also be pain-free (referred to as "compensated CMD") or accompanied by passages of pain to frequent and/or long-lasting pain. Long-term dysfunction can result in damage to parts of the masticatory apparatus, in particular to teeth (heavy attrition), periodontium (periodontitides) and temporomandibular joints (attrition, habitual luxation) and also to persistent neuropathies ("trigeminal neuralgia"). Clearly identifiable, disturbing or painful CMD should therefore be treated.
Mutual interaction between CMD in the cranial region, changes in posture and other further-removed sections of the locomotive system, (musculoskeletal system), e.g. head, neck, shoulders, vertebral column, hips, knee and feet) as well as psychological factors often render interdisciplinary collaboration therapeutically practical, for instance between the dentist, orthopaedist, physiotherapist, psychotherapist etc.
Initially, easily reversible and/or less invasive (minimally invasive) treatment options are selected, such as short-term pain relief (using analgesics, cold or warm application), prevention and self-help (light food, movement and relaxation exercises), physical and physiotherapy, psychosomatic medicine and also removable splints. Different types of laboratory-fabricated splints are regularly used during treatment of CMD. The objectives of splint therapy include: reversing and re-orientation of the masticatory system, relaxation of the musculature; changing the position of the condylar head (retraction, reposition, distraction; protection of teeth and restorations against attrition, cracks, breaking off and protection of the periodontium against overloading.
Irreversible (invasive) treatment approaches (e.g. heavy systematic grinding-in, restoration, orthodontics, operations) are mainly reserved for serious courses of diseases.
CMD and other areas of dentistry are closely interrelated: CMD should be excluded or treated (to ensure success) before undertaking extensive (conservative or prosthetic) restorations, if necessary these will also be fitted to safeguard a new pain-free "therapeutic" occlusal relationship acquired during CMD treatment. Orthodontic treatment is intended to avoid favourable conditions for CMD, though it can also be used for its treatment. Conversely, CMD therapies can display orthodontic effects.
All aspects of CMD have been the subject of intensive technical dispute for decades between sometimes mutually exclusive approaches. In addition to terminology, aetiology, diagnostics, manifestation and meaning of CMD, all treatment approaches (whose evidence-base encounters systematic difficulties) are fundamentally called into question time and again.
Von uns erhalten Sie professionelle Unterstützung.
Treten Sie mit uns in Kontakt oder nutzen Sie unser Kontaktformular.
Deutsch | Englisch |
---|---|
Epoxydharz | epoxy resin |
Implantat-Suprakonstruktionen Implantat-Suprakonstruktionen Ober- und Unterkiefertotalprothese (Unterseite, mit Kugelkopfmatrizen)
Kugelkopf Eine S. kann rein implantatgetragen sein oder sich sowohl auf Zähnen, als auch auf Implantaten abstützen. Insbesondere bei Brücken spricht man dann von Hybrid- oder Verbund-Zahnersatz. Metallkeramikkronen auf Implantaten Bei zementierten S. ist zwischen provisorischer (temporärer), definitiver (permanenter) und semi-permanenter Zementierung zu unterscheiden. Letztere soll eine sichere Befestigung und gleichzeitig das Abnehmen der S. durch den Zahnarzt im Bedarfsfall ermöglichen. Damit handelt es sich um eine sogenannte bedingt abnehmbare (für den Patienten also festsitzende) S. Dazu gehören auch die verschraubten S. Die beiden Befestigungsarten bieten Vor- und Nachteile: Verschraubungen bedingen Spalträume, die bakteriell besiedelt werden können, zur Vorbeugung dagegen werden spezielle Gele zum Einbringen in den Implantat-Innenraum angeboten, die langfristig wirksam bleiben sollen. Erfolgt eine Fixation von S. mit Schrauben, können bei diesen auch Misserfolge durch Lockerung, Überlastung und Bruch auftreten. Da Implantate keine Eigenbeweglichkeit aufweisen und starr im Kieferknochen verankert sind, wird stets ein spannungsfreier Sitz von S. angestrebt. Er kann bei verschraubten S. auf mindestens zwei Pfeilern mit dem Sheffield-Test (spaltfreier Sitz bei Anziehen einer beliebigen Einzelschraube) überprüft werden. Um spannungsfreie Gerüste herzustellen, werden Verfahren zur intraoralen Verbindung (etwa Verkleben) von Teilen der S. und/oder zur digitalen Fertigung (z.B. Fräsen, Sintern) angewendet. Um unzugängliche Zementüberschüsse, die zu Periimplantitis und Implantatverlust führen können, zu vermeiden, sollte der Restaurationsrand zementierter S. stets im Bereich des Zahnfleischrands enden. Dies lässt sich – vor allem bei Implantatplattformen auf Knochenniveau ("bone level") mit entsprechenden (ggf. individuell angefertigten) Abutments erreichen. Abutments dienen als Verbindung zwischen Implantaten und S. Bei S. auf mehreren Pfeilern ermöglichen abgewinkelte Formen die Parallelisierung hin zu einer gemeinsamen Einschubrichtung. Abutments können entweder die Form eines präparierten Zahnstumpfs nachahmen oder eine Komponente eines Verbindungselements (z.B. Druckknopfsysteme, Kugelköpfe, Stege, Magnete) beinhalten. Die S. umfasst in diesen Fällen die entsprechenden ergänzenden Komponenten. |